Generated reference › Data Store Write — Control Systems/Signal Routing
kind: generated#block#control-systems-signal-routing

Data Store Write — Control Systems/Signal Routing

Control_Systems/Signal_Routing/Data_Store_Write · 1 input / 0 output port(s) at insert · exports to Python, MATLAB, Java, Rust, C, C++, VHDL, Verilog, SystemVerilog, PLC Structured Text

Description#

The block's own DESCRIPTION_HTML, rendered verbatim — the same text the config dialog's info panel and the library navigator show. Fix a wrong sentence in the block's .cpp (R-D9), never here.

Data Store Write

Control Systems / Signal Routing

Writes its input into the data store it names: the store = u, from this step on, for every Data Store Read of it, with no wire between them. Simulink’s Data Store Write (BlockType=DataStoreWrite).

Ports

  • Input – u, the value written. It must be the size of the store exactly; nothing is expanded or cast into a store, as Simulink casts nothing.

Parameters

  • Data store name – A (default). The store to write: the Data Store Memory of that name at this block’s level or the nearest level above it. Case-sensitive, and never looked up in the variables space. A name no Memory declares on that path – a Memory in a subsystem below this block included – stops the run in Simulink’s words (DSMemoryBlockNotFound).
  • Sampling Time (s) – zero or less inherits the solver’s rate; a positive value runs the block at that period.

Code export

All ten targets: Python, MATLAB, Java, Rust, C, C++, VHDL, Verilog, SystemVerilog and PLC Structured Text copy the input into the store, the exported core’s named global (ds0, …), element by element; in the three HDLs it goes through the working copy every signal takes, so a Read later in the same step sees it. An export that does not hold the store is refused by name.

Simulink bridge

Both directions, as simulink/Signal Routing/Data Store Write. Data store name goes to DataStoreName; "Sampling Time (s)" goes to SampleTime, as on every block. Simulink’s element selection (DataStoreElements, EnableIndexing) does not cross: a Write here writes the whole store.

Notes

  • A Write runs before the Reads of its store in the same step wherever no data path says otherwise. Two Writes of one store in a step run in their order, and the last one wins; its Memory’s Write after write diagnostic reports that, as a warning by default.
  • It writes once per step, never at a continuous solver’s intermediate stages. Its Memory’s Write after read diagnostic is checked on each write.

Code facts#

FactValue
registered typeControl_Systems/Signal_Routing/Data_Store_Write
familyControl_Systems/Signal_Routing
solver environment classICoreBlock_0_Control_Systems_1_Signal_Routing_2_Data_Store_Write
sourcesrc/ICoreBlocks/ICoreBlockLibrary/Blocks/Control_Systems/Signal_Routing/Data_Store_Write/ICoreBlock_0_Control_Systems_1_Signal_Routing_2_Data_Store_Write.cpp
headersrc/ICoreBlocks/ICoreBlockLibrary/Blocks/Control_Systems/Signal_Routing/Data_Store_Write/ICoreBlock_0_Control_Systems_1_Signal_Routing_2_Data_Store_Write.h
default size on canvas80 × 60 px
ports at insert1 in, 0 out
code generators implementedPython, MATLAB, Java, Rust, C, C++, VHDL, Verilog, SystemVerilog, PLC Structured Text

Ports#

#DirectionSignal typeDescription label
1inICoreDouble—

Ports the constructor creates. A block whose port list changes with its configuration adds or removes ports at load time; the count above is the one a freshly inserted block has.

Configuration variables#

Config variableDefaultSimulink parameter
Data store nameADataStoreName

Every block also carries Sampling Time (s) from ICoreBlockSolverEnvironment: zero or less inherits the solver's rate, a positive value runs the block at that period.

supportSupport::Both
Simulink pathsimulink/Signal Routing/Data Store Write
port-count rulePortsParam::None
SampleTime parameteryes
ICore configSimulink parameterValue translation
Data store nameDataStoreNamepasses through

Caveat (shown to the user): The whole store crosses: Simulink's element selection (DataStoreElements, EnableIndexing) does not.

Catalog contract: src/ICoreBlocks/ICoreCoder/ICoreCommandSystem/SimulinkBridge/ICoreSimulinkBlockCatalog.h

Description vs code#

The checker has a blind spot here — it could not resolve something (a grouped port bullet, a computed config name), which is reported and never counted as a pass. A reader has to settle it:

  • B0 no sample under docs/generated/samples/ — nothing to cross-check (P8.1)

The verdict above is tools/docs/check_block_descriptions.py (P7.1), which compares LISTS. It cannot read a sentence: "stateless" on a block with a state, an initial-value semantic the recursion does not implement, a "not synthesizable" caveat the HDL banner contradicts. That is the agent audit (P7.3) on BLOCK_DESCRIPTION_AUDIT.md, and this tool's green is not a substitute for one.

Sample results#

No sample run is committed for this block. Samples come from the headless harness (DOCS_PLAN.md P8.1) into docs/generated/samples/; until one exists this block's behaviour is witnessed by the parity and export-verification suites, not by a plot here.