Generated reference › Sinh — Control Systems/Trigonometry
kind: generated#block#control-systems-trigonometry

Sinh — Control Systems/Trigonometry

sinh

Control_Systems/Trigonometry/Sinh · 1 input / 1 output port(s) at insert · exports to Python, MATLAB, Java, Rust, C, C++, VHDL, Verilog, SystemVerilog, PLC Structured Text

Description#

The block's own DESCRIPTION_HTML, rendered verbatim — the same text the config dialog's info panel and the library navigator show. Fix a wrong sentence in the block's .cpp (R-D9), never here.

Sinh

Control Systems / Trigonometry

Outputs the hyperbolic sine of the input: y = sinh(u) = (exp(u) − exp(−u)) / 2, applied entry by entry, so a matrix signal is transformed element for element.

Defined for every real input, and unbounded: it grows exponentially.

Ports

  • Input – the signal u, of any size [m,n], applied entry by entry.
  • Output – the result y, of the SAME size [m,n]. The block never reshapes a signal.

Parameters

  • Sampling Time (s) – zero or less inherits the solver's rate; a positive value runs the block at that period.

Code export

All ten targets: Python, MATLAB, Java, Rust, C, C++, VHDL, Verilog, SystemVerilog and PLC Structured Text. There is nothing to tune, so nothing is exposed as a parameter on the generated core.

The seven software targets agree exactly, and at a pole or out of domain they all produce the same IEEE NaN or ±Inf.

The three HDL targets are simulation-only. There is no fixed-point sinh in the Q16.16 datapath to call, so the generated cores convert at the port boundary and evaluate in real arithmetic – correct in simulation, but not offered as synthesizable.

Simulink bridge

Export only, to simulink/Math Operations/Trigonometric Function with Operator fixed at sinh. The block has no parameters of its own, so besides that operator the only pair is the global one: "Sampling Time (s)" to SampleTime, as on every block. Three further parameters are always written out because this block offers no choice behind them – ApproximationMethod is None, which pins Simulink to the exact library function rather than its CORDIC or lookup approximation; OutputSignalType is real; and AngleUnit is radian.

Why export only. Import of that Simulink block belongs to Control Systems / Base Blocks / Trigonometric Function, which carries the operator as a config variable and so can represent all thirteen. If this block claimed the import as well, two ICore types would answer to one Simulink path and which of them an imported model resolved to would depend on link order. Exporting is unambiguous in the other direction, because it starts from the ICore type.

Notes

  • Algebraic, with no state: the output depends only on the current input.
  • Not linear, so the block deliberately carries no state space and model reduction reports it as unmergeable.
  • Odd, and sinh(0) = 0.
  • Grows exponentially: an input beyond about 710 overflows a double to ±Inf in every target, and the three HDL targets saturate far sooner – Q16.16 stops at about 32768, which sinh reaches by u ≈ 11.

Code facts#

FactValue
registered typeControl_Systems/Trigonometry/Sinh
familyControl_Systems/Trigonometry
solver environment classICoreBlock_0_Control_Systems_1_Trigonometry_2_Sinh
sourcesrc/ICoreSDK/ICoreBlockLibrary/Blocks/Control_Systems/Trigonometry/Sinh/ICoreBlock_0_Control_Systems_1_Trigonometry_2_Sinh.cpp
headersrc/ICoreSDK/ICoreBlockLibrary/Blocks/Control_Systems/Trigonometry/Sinh/ICoreBlock_0_Control_Systems_1_Trigonometry_2_Sinh.h
default size on canvas70 × 70 px
ports at insert1 in, 1 out
code generators implementedPython, MATLAB, Java, Rust, C, C++, VHDL, Verilog, SystemVerilog, PLC Structured Text

Ports#

#DirectionSignal typeDescription label
1inICoreDouble
2outICoreDouble

Ports the constructor creates. A block whose port list changes with its configuration adds or removes ports at load time; the count above is the one a freshly inserted block has.

Configuration variables#

No config variable beyond the Sampling Time (s) every block carries.

Every block also carries Sampling Time (s) from ICoreBlockSolverEnvironment: zero or less inherits the solver's rate, a positive value runs the block at that period.

supportSupport::ExportOnly
Simulink pathsimulink/Math Operations/Trigonometric Function
port-count rulePortsParam::None
SampleTime parameteryes
always setOperator = sinh, ApproximationMethod = None, OutputSignalType = real, AngleUnit = radian

Caveat (shown to the user): exports to Simulink's Trigonometric Function with Operator fixed at 'sinh'. IMPORT of that block belongs to Base_Blocks/Trigonometric_Function, which carries the operator as a config variable and so can represent all thirteen -- two ICore types answering to one Simulink path would make an imported model resolve by link order

Catalog contract: src/ICoreSDK/ICoreCoder/ICoreCommandSystem/SimulinkBridge/ICoreSimulinkBlockCatalog.h

Description vs code#

The lists agree. check_block_descriptions.py finds no disagreement between the description's Ports, Parameters, Code export and Simulink bridge lists and the code's.

The verdict above is tools/docs/check_block_descriptions.py (P7.1), which compares LISTS. It cannot read a sentence: "stateless" on a block with a state, an initial-value semantic the recursion does not implement, a "not synthesizable" caveat the HDL banner contradicts. That is the agent audit (P7.3) on BLOCK_DESCRIPTION_AUDIT.md, and this tool's green is not a substitute for one.

File banner (developer view)#

The top comment of the block's .cpp — the maths, the realization and the export strategy, addressed to whoever changes it. It must not contradict the description above (P7.5).

Sinh -- y = sinh(u) = (exp(u) - exp(-u)) / 2 One function, fixed: the block IS y = sinh(u) = (exp(u) - exp(-u)) / 2.

Algebraic and stateless. No state space -- see the header for why.

Every target calls its own library function rather than rebuilding the maths, with the two exceptions the family shares: Java and IEC Structured Text have no inverse hyperbolics and build those from logarithms.

Sample results#

Sinh — Repeating Sequence Stair: [-2 -1 -0.5 0 0.5 1 2 3], one entry per sampleSinh — Repeating Sequence Stair: [-2 -1 -0.5 0 0.5 1 2 3], one entry per sample0510-2-10123inputoutput
tin ICoreDouble-Out-0out ICoreDouble-Out-0
0-2-3.627
0.40.50.5211
0.8-2-3.627
1.20.50.5211
1.6-2-3.627
20.50.5211
2.4-2-3.627
2.80.50.5211
3.2-2-3.627
3.60.50.5211
4-2-3.627
4.40.50.5211
4.8-2-3.627
5.20.50.5211

Every 4th of 60 samples, from the table stimulus.

The same rig also ran:

StimulusWhat it isOutput range
impulseImpulse: one sample of 1 at k = 5, 0 elsewhere (Repeating Sequence Stair)0 … 1.175
rampRamp: slope 1 from t = 00 … 165.1
sineSine Wave: amplitude 1, 2 rad/s, no phase, no bias-1.175 … 1.175
stepStep: 0 -> 1 at t = 1 s0 … 1.175

Plotted: table — Repeating Sequence Stair: [-2 -1 -0.5 0 0.5 1 2 3], one entry per sample

Category static · sample time 0.1 · 60 steps · commit ccf005c8 · produced by docsSample --out <folder> --steps 60 · data docs/generated/samples/Control_Systems__Trigonometry__Sinh.json · the SVG is generated from those numbers by tools/docs/plot_svg.py, so it is a run and not a drawing (R-D10).